Hospitals and health systems are working to address the environmental risks associated with the care of patients at risk for suicide and self-harm. The Centers for Medicare & Medicaid Services (CMS) is currently creating comprehensive interpretive guidance, which will incorporate Joint Commission patient safety recommendations. To help hospitals and other health care facilities understand and implement these recommendations, ASHE is developing tools and resources for members.

Advocacy Alert: Ligature Risk Interpretive Guidelines

The Centers for Medicare & Medicaid Services (CMS) is requesting public comments regarding Ligature Risk Interpretive Guidelines by June 17, 2019. The request recommends several updates to the December 8, 2017 S&C Letter Clarification on Ligature Policy.

ASHE is requesting that members share their concerns and comments regarding the proposed guidance.

Share Comments with ASHE View CMS Memorandum

Key Resources:

just-ask-ashe-150x85.png
ASHE On Demand: 2019 Q2–Just ASK ASHE High Risk Video Monitoring

Watch Now Share Your Comments

safe-health-care-environment-150x85.png

Three-step ligature risk guidance for general acute care or emergency departments

ASHE recommends a three-step approach to managing ligature risks and preventing patient self-harm in general acute care or emergency departments. These steps do not apply for psychiatric units.

step-01-200x115.png
Step 1: Identify
Identify patients who are currently at risk for intential harm to themselves or others. Steps 2 and 3 only need to be taken with patients who are identified as a risk.

step-02-200x115.png
Step 2: Observe
Provide 1:1 monitoring of at-risk patients with continuous visual observation. The person observing the patient needs to be able to intervene immediately. Video observation is not appropriate since the video monitoring process cannot provide immediate intervention.

Some states require privacy in certain situations, such as when the patient is using the bathroom. In these instances, since 1:1 observation is not possible, the bathroom used by the patient must be ligature resistant. Converting a bathroom to a ligature-resistant environment can affect fire and life safety regulations and ADA compliance issues. Health care organizations should conduct a careful review of the rules and regulations that apply to their specific facilities.

step-03-200x115.png
Step 3: Remove
In any cases where 1:1 continuous observation is not feasible, hospitals must remove or clinically mitigate all environmental risks. Loose items should be removed from the patient area. Fixtures installed in the room do not need to be removed; however, patient access to certain areas may need to be restricted to prevent patients from reaching items that they could use for self-harm.